<p>Electric centrifuge function and purpose:</p><p>The centrifuge is a conventional laboratory centrifuge, which is widely used in scientific research, education and production departments such as biology, chemistry, medicine, etc., and is suitable for the rapid separation and synthesis of trace samples.</p><p></p><p>Safety instructions for electric centrifuges:</p><p>(1) If the power indicator does not light up when the machine is turned on, it should be shut down immediately for inspection.</p><p>(2) It is strictly forbidden to run without load without the rotor installed.</p><p>(3) Check the rotor for corrosion damage before operation.</p><p>(4) Do not open the centrifuge cover when the rotor is running, and do not touch the running rotor.</p><p>(5) It is strictly forbidden to operate the rotor under unbalanced loading.</p><p></p><p>Electric centrifuge Instructions for use:</p><p>(1) The working platform of the centrifuge should be flat and firm, and the working room should be neat and clean, dry and well ventilated.</p><p>(2) Turn on the power switch, the instruction light is on.</p><p>(3) Turn off the power switch.</p><p>(4) Open the centrifuge cover and wipe the inner cavity and rotor clean.</p><p>(5) Install test tubes of consistent weighing.</p><p>(6) Close the centrifuge cover.</p><p>(7) Set the timing</p><p>(8) Turn on the power switch</p><p>(9) Adjust the speed control knob to the required speed.</p><p>(10) Before stopping each time, the speed control knob must be set to the minimum position, the timer must be set to zero, and then the power switch must be turned off.</p><p>(11) Wipe the inner cavity and rotor, and close the centrifuge cover.</p><p></p><p>80-1 Electric Centrifuge Maintenance:</p><p>(1) Do not place any material on the centrifuge cover. After each use, be sure to clean the inner cavity and rotor.</p><p>(2) If the centrifuge has not been used for a long time, the centrifuge cover should be opened for a period of time before use to dry the inner cavity.</p><p>(3) The carbon brush of the motor should be replaced in time after 3000 hours of use to avoid wearing the commutator.</p><p>(4) It is normal for the centrifuge to wear out after long-term use. The company will continue to provide quality services.</p><p>Related Products:centrifuge machine,centrifuge,prp centrifuge machine,lab centrifuges,centrifuge for prp,centrifuga,lab benchtop centrifuge machine,lab machine,high-speed centrifuge</p>
| Maximum speed | 0 OPM |
|---|---|
| Brand | LilyStore |
| Features | Timer |
| Minimum speed | 0 OPM |
| Power type | Corded Electric |
| Weight | 8000 g |
| Has written warranty | No |
| Model | 80-1 |
If you notice any omissions or errors in the product information on this page, please use the correction request form below.
Correction Request Form